EXFO FTB-7423B Singlemode OTDR Module
In today?s competitive market, high-performance, easy-to-use OTDRs are more essential than ever for installing, maintaining and troubleshooting networks. With the new FTB-7000B and FTB-70000C series OTDR modules from EXFO, you get the right tools to precisely detect and analyze fiber splices, connectors, breaks and other events along a fiber link. The FTB-7000B series delivers a wide choice of OTDRs to conveniently test the range of optical networks out there.
Features:
Specifications:
For full EXFO FTB-7423B product specifications, please click here: EXFO FTB-7423B
In today?s competitive market, high-performance, easy-to-use OTDRs are more essential than ever for installing, maintaining and troubleshooting networks. With the new FTB-7000B and FTB-70000C series OTDR modules from EXFO, you get the right tools to precisely detect and analyze fiber splices, connectors, breaks and other events along a fiber link. The FTB-7000B series delivers a wide choice of OTDRs to conveniently test the range of optical networks out there.
Features:
- Reduced trace noise: catch low-loss events
- Short dead zones: detect closely spaced events
- Four-point loss measurements: measure event loss and reflectance accurately
- Optical return loss (ORL) calculation: pinpoint the backreflection level of singlemode networks, components and connectors
- Quick startup: reach 90% of maximum dynamic range in under 30 seconds
- Fast acquisition, fast analysis: a trace starting at 7 seconds
- High sampling counts: locate events with unparalleled precision
- Down to 8 cm sampling resolution: pinpoint fault locations with extreme accuracy
Specifications:
| Wavelength (nm) | Dynamic range (dB) at 10 µs | Dynamic range (dB) at 20 µs | Event dead zone (m) | Attenuation dead zone (m) |
| 1310 ± 20/1550 ± 20 | 40/38 | 41.5/39.5 | 3/3 | 10/15 |
| General Specifications | ||||
| Distance range (km) | 1.25, 2.5, 5, 10, 20, 40, 80, 160, 260 | |||
| Pulse width (ns) | 10, 30, 100, 275, 1000, 2500, 10 000, 20 000 | |||
| Linearity (dB/dB) | ± 0.05 | |||
| Loss threshold (dB) | 0.01 | |||
| Loss resolution (dB) | 0.001 | |||
| Sampling resolution (m) | 0.08 to 5 | |||
| Sampling points | Up to 52 000 | |||
| Distance uncertainty | ± (1 m + 0.0025 % x distance) | |||
| Measurement time | User-defined (60 min maximum) | |||
| Real-time refresh | < 1 s | |||
| Stable source output power (dBm) | -5 | |||
For full EXFO FTB-7423B product specifications, please click here: EXFO FTB-7423B