Fluke i5s 600V AC Current Clamp Probe
$1,095.00
Availability:
Out of stock
SKU
11H94
Condition: Refurbished
Warranty: 90 Day Exchange
Shipping: USA & Worldwide
Request a Quote for
- (3) Fluke i5s AC Current Clamp (BC# 23233M-L/T* 23234M-L/T* 23235M-L/T*)
Introduction
The i5s (hereafter called the “Current Clamp”) is compatible with any instrument that can accept a standard BNC connector and is capable of ac millivolt measurements; the Current Clamp can also be used with digital multimeters using a BNC-to-dual banana plug adapter. The Current Clamp produces an output of 400 mV ac per 1 A ac input level.
Key Features:
- Low level current clamp measures up to 5 A AC
- Compact shape makes transporting and storing convenient; the clamp measures only 116 x 43 x 23 mm (4. 6 x 1.7 x .9 in)
- Take accurate readings without breaking the circuit
- CAT III 600 V (For insulated conductors only)
Instrument Compatibility
The Current Clamp is compatible with any Fluke Multimeter or any other current measurement device that has the following features:
- BNC or Banana inputs
- Input accuracy of 1 % or better to take full advantage of the accuracy of the Current Clamp.
- Input impedance of > 1 M Ω in parallel with up to 47 pF
Measurement Considerations
- Center the conductor inside the Current Clamp jaw.
- Make sure the Current Clamp is perpendicular to the conductor.
- For optimal reading, make sure the conductor is centered in the jaws of the Current Clamp.
Observe the following Guidelines when making measurements:
- Avoid taking measurements close to other current-carrying conductors.
| Fluke
i5s Clamp Specifications |
|
| Electrical
Specifications |
|
| Reference Conditions |
23 ± 5 °C, 20 to 75 % RH; conductor centered in jaw opening; no DC component; no adjacent conductor. |
| Measurement Range |
10 mA to 6 A |
| Output |
400 mV/A |
| Accuracy |
(48 Hz to 65 Hz): 10 mA to 1 A 1% + 5 mA 1 A to 5 A 1% |
| Phase Shift |
(48 Hz to 65 Hz): 10 mA to 100 mA Unspecified 100 mA to 5 A 4 ° |
| Crest Factor |
≤ 3, add 0.7 % to accuracy |
| Typical Bandwidth |
40 Hz to 5 kHz |
| Working Voltage |
600 V ac rms, in compliance with
EN61010 |
| Common Mode Voltage | 600 V ac rms from earth ground, in compliance with EN61010 |
| Input Load Impedance (of host instrument) | >1 M Ω in parallel with up to 47 pF |
| Maximum Non-destructive Current |
70 A |
| Duty Cycle |
0.01 A to 6 A continuous |
| Influence Of Adjacent Conductor |
≤ 15 mA/A (@ 50/60 Hz) |
| Influence of Conductor Position
in Jaw Opening |
±0.5 % of reading (@ 50/60 Hz) |
| General
Specifications |
|
| Output |
2.5 m |
| Maximum Conductor Size |
15mm |
| Storage Temperature |
-20°C to 60°C |
| Operating Temperature |
0 °C to 50 °C |
| Relative Humidity |
10 °C to 30 °C: 85 % 30 °C to 40 °C: 75 % 40 °C to 50 °C: 45 % |
| Temperature Coefficient |
: 0.01 % X (specified accuracy)/ °C (< 18 °C or > 28 °C) |
| Altitude |
2000 m; Non-operating: 12000 m |
| Dimensions |
116 x 43 x 23 mm |
| Weight |
200 g |
| Included |
|
|---|