Fluke Networks OFTM-5732 module sources

Fluke Networks OFTM-5732 SM Fiber OTDR Module w/ Power Meter VFL

Fluke Networks OF-500 OptiFiber SM MM Fiber OTDR

Fluke Networks OF-500 OptiFiber SM MM Fiber OTDR

Fluke Networks OptiFiber OFTM-5612B 850nm 1300nm MM OTDR Module

$395.00
Availability: Out of stock
SKU
1H214

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Shipping: USA & Worldwide

Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

  • Fluke Networks OFTM-5612B MultiMode OTDR Module (BC# 41944-L/T*)
    • Source:
      • 850nm
      • 1300nm
    • Power Meter:
    • 850nm
    • 1300nm
    • 1310nm
    • 1550nm

 Fluke Networks OFTM-5612B MMOTDRModule


When used in conjunction with the Fluke Networks OptiFiber, the Fluke Networks OptiFiber OFTM-5612B Multimode OTDR & PM Module provides the ability to run OTDR, Power Meter, and loss length tests for multimode               
 

Specifications
Output/input connector SC/UPC removeable/cleanable
Wavelengths 850 ± 20 nm and 1300 ± 25 nm
Fiber types tested 50/125 µm or 62.5/125 µm multimode
Event deadzone 850 nm: 0.5 m typical
1300 nm: 1.3 m typical
Attenuation deadzone 850 nm: 4.5 m typical
1300 nm: 10.5 m typical
Pulse width 850 nm: 4 ns, 20 ns
1300 nm: 8 ns, 40 ns, 100 ns, 200 ns,
400 ns, 650 ns
Max distance range 850 nm: 3 km, 1300 nm: 7 km
Dynamic range 850 nm: 15 dB typical
1300 nm: 14 dB typical
Testing speed <10s for two wavelengths at 2 km with 25 cm resolution
<30s for two wavelengths at 400 m with 3 cm resolution
Output power 850 nm: >110 mW-pk
1300 nm: >22 mW-pk
Distance accuracy ± 1 m ± 0.005% of distance ± 50% of resolution ± IOR error ± event location error
Loss threshold .2 dB
Linearity ± .07 dB/dB
Sample resolution 3 cm to 50 cm
Reflectance accuracy ± 4 dB
ORL accuracy ± 4 dB
Laser classification Class 1 CDRH, complies to EN 60825-2

 

Input/output connectors Removable/interchangeable input connector; SC/PC output connector
Nominal output wavelengths LED source: 850 nm and 1300 nm
Measurement range 5 km of 62.5 µm or 50 µm multimode fiber; 20 km in far-end source mode
Power measurement detector type InGaAs
Calibrated wavelengths for power measurment 850 nm, 1310 nm, 1550 nm
Power measurement range 0 to -60 dBm (1300/1310 nm and 1550 nm); 0 to -52 dBm (850 nm)
Output power (nominal) OFTM-5612B: -19.5 dBm; OFTM-5732: -7 dBm





For full Fluke Networks OFTM-5612B product specifications, please click here: Fluke Networks OFTM-5612B