AFL Noyes OLS 2 SM Fiber Laser Light Source
$0.00
Availability:
Out of stock
SKU
4P164
Condition: Refurbished
Warranty: 90 Day Exchange
Shipping: USA & Worldwide
Request a Quote for
- AFL Noyes OLS 2 SingleMode Fiber Optic Laser Source (BC# 19563)
- SM Source:
- 1550nm
- FC Connector For Source
- SM Source:
- (2) SM FC-FC Fiber Cables
- User Manual On CD-ROM
- Carrying Case
Noyes OLS 2 Fiber Light Source
The OLS 2 laser source series offers excellent stability and portability for accurate fiber optic testing. Four versions of the OLS 2 are offered for measurements at 1310 nm, 1550 nm, 1625 nm, and dual wavelength (1310/1550 nm). These compact units operate in either continuous wave (CW) mode or 2 kHz modulated mode.
With an output power of -10 dBm, the OLS 2 will provide in excess of 50 dB range when used with Noyes Fiber Systems optical power meters.
The OLS 2 operates on disposable batteries or AC adapter. A Low battery indication warns the user that battery replacement is necessary. The optical output is via a top panel FC, SC, or ST connector. The output may be equipped with other style connectors upon request.
When used with an optical power meter, the OLS 2 laser source provides an inexpensive alternative to higher priced loss test sets. The OLS 2 may be substituted for terminal equipment in the central office or head-end to provide a stable output for loss measurements.
For singlemode applications, such as Telecom or CATV, the OLS 2 may be coupled with an optical power meter as a test kit to perform optical loss tests at 1310 or 1550nm.
In the modulation mode, the OLS 2 applies a 2 kHz tone into the fiber. This signal is detected by the OFI-200B, optical fiber identifier, to isolate specific fibers in a bundle prior to splicing or rerouting.
Applications
When used with an optical power meter, the OLS 2 laser source provides an inexpensive alternative to higher priced loss test sets. The OLS 2 may be substituted for terminal equipment in the central office or head-end to provide a stable output for loss measurements.
For singlemode applications, such as Telecom or CATV, the OLS 2 may be coupled with an optical power meter as a test kit to perform optical loss tests at 1310 or 1550 nm.
In the modulation mode, the OLS 2 applies a 2 kHz tone into the fiber. This signal is detected by the OFI-200B, optical fiberidentifier, to isolate specific fibers in a bundle prior to splicing or rerouting.
Specifications:
For full Noyes OLS 2 product specifications, please click here: Noyes OLS 2
The OLS 2 laser source series offers excellent stability and portability for accurate fiber optic testing. Four versions of the OLS 2 are offered for measurements at 1310 nm, 1550 nm, 1625 nm, and dual wavelength (1310/1550 nm). These compact units operate in either continuous wave (CW) mode or 2 kHz modulated mode.
With an output power of -10 dBm, the OLS 2 will provide in excess of 50 dB range when used with Noyes Fiber Systems optical power meters.
The OLS 2 operates on disposable batteries or AC adapter. A Low battery indication warns the user that battery replacement is necessary. The optical output is via a top panel FC, SC, or ST connector. The output may be equipped with other style connectors upon request.
When used with an optical power meter, the OLS 2 laser source provides an inexpensive alternative to higher priced loss test sets. The OLS 2 may be substituted for terminal equipment in the central office or head-end to provide a stable output for loss measurements.
For singlemode applications, such as Telecom or CATV, the OLS 2 may be coupled with an optical power meter as a test kit to perform optical loss tests at 1310 or 1550nm.
In the modulation mode, the OLS 2 applies a 2 kHz tone into the fiber. This signal is detected by the OFI-200B, optical fiber identifier, to isolate specific fibers in a bundle prior to splicing or rerouting.
Applications
When used with an optical power meter, the OLS 2 laser source provides an inexpensive alternative to higher priced loss test sets. The OLS 2 may be substituted for terminal equipment in the central office or head-end to provide a stable output for loss measurements.
For singlemode applications, such as Telecom or CATV, the OLS 2 may be coupled with an optical power meter as a test kit to perform optical loss tests at 1310 or 1550 nm.
In the modulation mode, the OLS 2 applies a 2 kHz tone into the fiber. This signal is detected by the OFI-200B, optical fiberidentifier, to isolate specific fibers in a bundle prior to splicing or rerouting.
Specifications:
| Optical Specifications | |
| Output Wavelength (nm) | 1550 + 20 |
| Output Power | -10 dBm |
| Laser Classification | Class 1 |
| Output Connector | FC, SC, or ST |
| Modes of Operation | CW and 2 kHz |
| Special Width | 5 nm typical |
| Stability | + 0.1 dB over 1 hours |
| General Specifications | |
| Power | 9V Battery or AC Adapter (optional) |
| Operating Temperature | 0° to 40°C |
| Storage Temperature | -10° to 50°C |
| Size (H x W x D) | 4.5 x 75 x 1.0 in (11.5 x 7.0 x 2.5 cm) |
| Weight | 1 lb. (0.45 kg) |
For full Noyes OLS 2 product specifications, please click here: Noyes OLS 2
| Included |
|
|---|