Noyes OLS2 Dual kit with accessories

AFL NOYES OLS2 DUAL SM Fiber Optic Source w/ WaveID OLS2-DUAL

Noyes OLS 2 kit with accessories

AFL Noyes OLS 2 SM Fiber Laser Light Source

AFL Noyes OPM5 OLS2D SM Fiber Loss Test Set

$1,095.00
Availability: In stock
SKU
4P146

Condition: Refurbished

Warranty: 1 YEAR WARRANTY

Shipping: USA & Worldwide

  • AFL Noyes OPM5-3C Optical Power Meter (BC# 18014-L/T*)
    • Power Meter:
      • 850nm
      • 1300nm
      • 1310nm
      • 1550nm
    • ST Connector For Power Meter
  • Noyes OLS2D Dual SingleMode Laser Source (BC# 18015-L/T*)
    • SM Source:
      • 1310nm
      • 1550nm
    • ST Connector For Source
  • (2) SM ST-ST Fiber Cables
  • User Manual On CD-ROM
  • Carrying Case (G)
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

Noyes OPM5 Power Meter

The OPM 5 is used to perform diagnostic and evaluation measurements associated with fiber optic transmission systems  and cable plant. Applications for the OPM 5 will be found within the telecommunication, cable television, data network, and  industrial control industries. 

The OPM 5 measures absolute power (in dBm or µW ) and loss (dB). Absolute power expressed in dBm is the amount of  optical power received by the detector as compared to 1mW (0dBm=1mW). Measuring dBm is useful for verifying the output  power of a transmitter and determining system losses. 

Loss is the difference in optical power from a known input (the reference level) and the output power at the opposite end of  the fiber under test. The OPM 5 can display dB loss directly after a reference level has been set. Loss measurements are  used to qualify cable plant links and fiber optic jumpers.

Microwatts is also a way to measure absolute power. Some manufacturers specify their transmission equipment in watts  instead of dBm. The OPM 5 offers the ability to measure watts for convenience when verifying output power of transmitters. For accurate results, always be sure to set the OPM 5 to measure the same wavelength as the output of the optical light  source.

 

OPM5-3C Specifications:

Optical OPM5-3C
Calibrated wavelengths 850, 1300, 1310, 1550nm
Detector type InGaAs
Tone detect range +6 to -30 dBm for 850nm
+6 to - 40 dBm
Accuracy ± 0.25 dB
Display Range +6 to -70 dBm
Resolution 0.01 dB
Measurement units dB, dBm, µW
General
Battery life 300 hours (2 x AA) 
Operating temperature -10 to 50°C, 90% RH (non-condensing)
Storage temperature -30 to 60°C, 90% RH (non-condensing)
Size (H x W x D) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in)
Weight 0.26 kg (0.58 lb)

NOYES OLS2-DUAL Optical Source

The OLS2-Dual laser source is a cost-effective, rugged, handheld instrument designed for performing insertion loss measurements on single-mode fiber optic links when used with an optical power meter. When paired with an optical fiber identifier, the OLS2-Dual may be
used for fiber identification. The LASER output is stabilized to ensure accurate test results per current TIA/EIA requirements.
The OLS2-Dual features 1310 nm and 1550 nm (or 1550 nm and 1625 nm) LASER output from a single output port and is easy to operate. This light source offers 4 modes of operation: Dual wavelengths sending ID, single wavelength sending ID, CW, and modulated Tone. [Active Output], [Tone], [Battery], and [External Power] indicators identify the currently enabled operating mode, battery charge status, and external power presence.
The OLS2-Dual output port is equipped with a UCI based removable adapter to allow the output connector to be inspected and cleaned.
In addition to being powered by two AA alkaline batteries, the OLS2-Dual can be powered by optional AC adapter and/or rechargeable NiMH battery pack. The OLS2-Dual is fully N.I.S.T. traceable.


Features
? Rugged, handheld, lightweight
? Dual wavelengths from a single port
? Certify single-mode links per TIA/EIA standards
? Dual Wave ID, single Wave ID, CW, and modulated Tone
? 270 Hz, 330 Hz, 1 kHz, and 2 kHz supported Tone (2 kHz default)
? AA alkaline, optional rechargeable NiMH battery pack or AC adapter
? Long battery life
? Low battery indicator
? Adjustable output
? Cost-effective, easy to use
? N.I.S.T. Traceable


Applications
? The OLS2-Dual may be substituted for terminal equipment in the central office or head end to provide a stable output for loss measurements.
? For single-mode applications, such as Telecom or CATV, the OLS2-Dual may be coupled with an optical power meter as a test kit to perform optical loss tests at 1310 and 1550 nm.
? In the modulation Tone mode, the OLS2-Dual generates a Tone signal into the fiber. This signal is detected by the OFI-200, optical fiber identifier, to isolate specific fibers in a bundle prior to splicing or rerouting.
 

Specifications:
Optical OLS2-Dual (single port)
Output wavelength (nm) 1310 ±20
1550 ±20
Output power 0 dBm*
Laser classification Class 1 (FDA 21 CFR 1040.1
and 1040.11, and IEC 60825-1)
Output connector ST
Spectral width (FWHM) 5 nm (max)
Stability ± 0.05 dB over 1 hour (after 15 min. warm-up)
± 0.1 dB over 8 hours (after 15 min. warm-up)
General
Power 2 x AA batteries, optional NiMH or AC adapter
Battery life (2 x AA) Typical 120 hours, Minimum 75 hours
Operating temperature -10 to 50°C, 90% RH (non-condensing)
Storage temperature -30 to 60°C, 90% RH (non-condensing)
Size (H x W x D) 5.5 x 3.2 x 1.5 in (14.0 x 8.1 x 3.8 cm)
Weight 0.65 lb (.29 kg)


For full Noyes OPM 5 OLS 2D product specifications, please click here: Noyes OPM 5 OLS 2D

More Information
Included
  • AFL Noyes OPM5-3C Optical Power Meter (BC# 18014-L/T*)
    • Power Meter:
      • 850nm
      • 1300nm
      • 1310nm
      • 1550nm
    • ST Connector For Power Meter
  • Noyes OLS2D Dual SingleMode Laser Source (BC# 18015-L/T*)
    • SM Source:
      • 1310nm
      • 1550nm
    • ST Connector For Source
  • (2) SM ST-ST Fiber Cables
  • User Manual On CD-ROM
  • Carrying Case (G)