Telefonix TF1 ToneRanger Cable Fault Locator
$0.00
Availability:
Out of stock
SKU
TE01
Condition: Refurbished
Warranty: 90 Day Exchange
Shipping: USA & Worldwide
Request a Quote for
- Telefonix TF1 ToneRanger Transmitter (BC# 11777)
- Telefonix TF1 ToneRanger Receiver
- 30 ft External Ground Wire
- Telefonix Humbucker Hand Coil
- Telefonix TFS1 Step by Step Guide
- Test Lead Cable
- Headset
- Hard Copy User Manual
- Strap For Transmitter
- Strap For Receiver
- Integrated Hard Case
Telefonix TF1 ToneRanger®
The ToneRanger® locates resistance faults in twisted pair cable by transmitting two simultaneous frequencies, which are microprocessor analyzed in the receiver. This achieves a reduction in the tone "carry-by" (tone audible beyond location of the fault) of 30 to 1. Increased sensitivity will locate faults to 100k ohms. The ToneRanger® is not fooled by cable size changes, gauge changes, water, hidden slack loops, bridge taps, capacitance build outs, or load coils. The ToneRanger® is accurate, reliable, cost effective, and significantly minimizes the amount of time it takes a user to locate and isolate a fault.
Features
-
It gives an exact location that is not subject to the TDR and RFL distance measuring errors.
-
Locates twisted pair resistance faults in aerial, underground, and direct buried cable.
-
Locates splits, opens, and bridge taps.
-
Uses low voltage and does not damage cable, circuit cards, C.O. or subscriber equipment.
-
Sends Pair ID tone through wet pulp and saves service outage time on small count section throws.
-
Locates open shields and shield to earth faults.
-
Does not interfere with DSL, IPTV, or digital services on adjacent lines.
Specifications:
| Tone Frequency | Maximum Pair Length | Cable Configuration |
| LO 145Hz [185Hz] | 16,000 ft. [5,000m] | Aerial / Buried |
| MED 335Hz [320Hz] | 7,000 ft. [2,000m] | Aerial / Buried |
| HI 985Hz [880Hz] | 2,000 ft. [700m] | Buried Only |
| Locatable Fault Range | ||||
| Fault | Aerial Max. | Buried Max. | Depth Max. | Buried Minimum TX Number |
| Short | 50k Ohms | 20k Ohms | 1 1/2 ft. [.5m] | 20 |
| Cross | 100k Ohms | 20k Ohms | 2 1/2 ft. [.8m] | 20 |
| Ground | 100k Ohms | 50k Ohms | 5 ft. [1.5m] | 10 |
| Split | Strapped | Strapped | 3 ft. [1m] | 5 |
| Wet Splice | 100k Ohms | 100k Ohms | 5 ft. [1.5m] | 10 |
| Included |
|
|---|